E550 Solvent-based Epoxy Topcoat

E550 solvent-based epoxy topcoat is a solvent-based two-component epoxy resin functional coating. This product has strong adhesion, durability, acid and alkali resistance, corrosion resistance, wear resistance, etc., and is waterproof, mildew-proof, and leak-proof. The construction is convenient, the material consumption is small, and the cost is low. It is suitable for ground protection in sports venues, industrial workshops, indoor parking lots, storage warehouses and other places with clean, wear-resistant, corrosion-resistant and water-resistant requirements.

Description

 【Main Feature】

The paint film has a soft luster and bright colors

Fast drying and long pot life

Good adhesion, wear-resistant and durable

 

【Detailed introduction】

E550 solvent-based epoxy topcoat is a solvent-based two-component epoxy resin functional coating. This product has strong adhesion, durability, acid and alkali resistance, corrosion resistance, wear resistance, etc., and is waterproof, mildew-proof, and leak-proof. The construction is convenient, the material consumption is small, and the cost is low. It is suitable for ground protection in sports venues, industrial workshops, indoor parking lots, storage warehouses and other places with clean, wear-resistant, corrosion-resistant and water-resistant requirements.

 

【Application scope】

For topcoat application in industrial plants, warehouses, underground parking lots, offices, etc., this product can also be used to prepare topcoat putty and be used to seal the ground before surface coating.

 

【Product Information】

The material is divided into two components: A and B.

Component A solid color viscous liquid 15kg/barrel

Component B yellow transparent liquid 6kg/barrel

Packaging: Printed metal packaging drum. It is recommended to stack it in three layers when stacking.

Storage: The storage temperature is 5-35℃. It should be stored in a cool, ventilated and dry warehouse, away from fire.

seeds, heat sources, and strictly prohibited from exposure to sunlight

 

【Technical data】

Status: Even after stirring, no lumps, no impurities

Adhesion: Level 1

Flexibility: Level 1

Hardness: >H

Wear resistance: <0.04

Drying time: Surface dry: less than 1 hour

Hard work: less than 24 hours

(Temperature is 25℃, relative humidity is 50%)

 

【Grassroots requirements】

The compressive strength of the concrete floor should be ≥20Mpa, the tensile strength should be ≥1.5Mpa, and the flatness should be ±4mm/2m based on ruler. The base surface must be dry, clean, and free of oil and other pollution.

 

【Construction Tips】

The construction environment must be clean, clean and dust-free to avoid affecting the coating effect.

The paint should be stirred evenly after opening the can to avoid color difference. ,

Construction should be stopped when the temperature falls below 5°C

It is not suitable for construction in humid weather. The ideal humidity for construction is 35%-80% (relative humidity)

 

【Construction Conditions】

Ground base temperature: 5-35℃

Construction environment temperature: 5-35℃

Ground base moisture content: <8%

Relative humidity of construction environment: <80%

 

【Construction methods/tools】

Dilution: 0-10%, depending on the actual conditions at the construction site

Construction method: brushing, rolling or spraying

Tools: roller brush

 

【Instructions for use】

Surface treatment: Before construction, dust, gravel, grease, and old coatings should be removed from the base surface, and cracks and holes should be smoothed with putty, primer should be used to seal the base surface, and epoxy intermediate paint should be scraped and leveled.

Theoretical dosage: about 3-4 square meters/kg (two passes of construction).

Ratio and opening time: The ratio of main agent to curing agent is 5:2 (weight ratio). It must be mixed and stirred strictly according to the ratio before use. Materials A and B should be used within 120 minutes after mixing. If the viscosity of the material is found to be significantly increased and it cannot be used anymore, it should be scrapped.

 

【Precautions】

For safe use of the product, please request the product safety data sheet (MSDS) from the manufacturer.

Construction workers should strengthen safety protection when using this product, and the construction environment should be kept ventilated.

This product is a flammable item and should be kept away from fire sources and flammable and explosive items during transportation, storage and construction.

For any unspecified matters, please contact local distributors or directly contact the factory.

 

【First-aid

Skin Contact: Wash with plenty of water and remove contaminated clothing and shoes.

Eye contact: Rinse with running water or saline and seek medical advice if necessary.

Inhalation: Move to fresh air and keep respiratory tract open. If you feel unwell, please seek medical attention.

Ingestion: clean mouth, induce vomiting, seek medical attention

 

【Fire-fighting measures】

Hazardous characteristics: Can burn when exposed to open flames. Hazardous combustion products: CO, CO2, etc.

Fire extinguishing methods and fire extinguishing media: dry powder, carbon dioxide, sand. Evacuate nearby and surrounding personnel. Fire extinguishers should wear pressure oxygen breathing apparatus and spray containers exposed to the fire with water to cool them and disperse and evaporate them.