Description
Detailed Introduction:
E552 anti-static epoxy self-leveling paint is a functional two-component epoxy topcoat with static discharge function and stable resistance. Floor coating used in places where static electricity needs to be eliminated must be used with the corresponding anti-static primer or anti-static intermediate paint. This product is environmentally friendly, solvent-free, has stable performance, is easy to use, and comes in a variety of colors. It is suitable for floor coating in various places with anti-static requirements.
Main Feature:
The paint film is full, bright and rich in color, smooth, smooth, beautiful and seamless.
Thick coating, high impact resistance and compressive strength, long service life
Stable performance and long-lasting anti-static effect
Application Scope:
Suitable for indoor floors with special anti-static requirements in enterprise workshops, warehouses, computer rooms, control centers, etc. in the fields of computers, electronics, electrical appliances, chemicals, telecommunications, printing, military factories, precision instrument manufacturing, etc.
Product Information:
The material is divided into two components: A and B.
Component A solid color viscous liquid 20kg/barrel
Component B viscous liquid 5kg/barrel
Packaging: Printed metal packaging drum. It is recommended to stack it in three layers when stacking.
Storage: The storage temperature is 5-35℃. It should be stored in a cool, ventilated and dry warehouse, away from fire and heat sources. It is strictly prohibited to expose it to the sun.
Technical data:
Status: Uniform, no lumps, no impurities
Bonding strength: ≥2.5MPa
Compressive strength: ≥60MPa
Hardness: >2H
Drying time: Surface dry: less than 6 hours
Hard work: less than 48 hours
(Temperature is 25℃, relative humidity is 50%)
Grassroots Requirements:
The compressive strength of the concrete floor should be ≥20Mpa, the tensile strength should be ≥1.5Mpa, and the flatness should be ±4mm/2m based on ruler. The base surface must be dry, clean, and free of oil and other pollutants.
Construction Tips:
The construction environment must be clean, clean and dust-free to avoid affecting the coating effect.
The paint should be stirred evenly after opening the can to avoid color difference.
Construction should be stopped when the temperature falls below 10°C
It is not suitable for construction in humid weather. The ideal humidity for construction is 35%-80% (relative humidity).
Construction Conditions:
Ground base temperature: 5-35℃
Construction environment temperature: 5-35℃
Ground base moisture content: <8%
Relative humidity of construction environment: <80%
Construction methods/tools:
Dilution: 0-5%
Construction method: Scrape coating with trowel, defoaming with defoaming roller, and assist in arranging conductive fibers.
Instructions for Use:
Surface treatment: Before construction, dust, gravel, grease, and old coatings should be removed from the base surface, and cracks and holes should be smoothed with putty, primer should be used to seal the base surface, and epoxy intermediate paint should be scraped and leveled.
Theoretical dosage: about 0.8-1 kg/square meter.
When proportioning and opening: the proportion of main agent and curing agent is 4:1 (weight ratio), and must be mixed and stirred strictly according to the proportion before use. Materials A and B should be used within 30 minutes after mixing. If the viscosity of the material is found to be significantly increased and it cannot be used anymore, it should be scrapped.
Precautions:
For safe use of the product, please request the product safety data sheet (MSDS) from the manufacturer.
Construction workers should strengthen safety protection when using this product, and the construction environment should be ventilated
For any unspecified matters, please contact local distributors or directly contact the factory.
First-aid:
Skin Contact: Wash with plenty of water and remove contaminated clothing and shoes
Eye contact: Rinse with running water or saline, seek medical attention in serious cases
Inhalation: Move to fresh air and keep respiratory tract open. If you feel unwell, seek medical advice.
Ingestion: Clean up leftovers in the mouth, induce vomiting, seek medical attention
Fire-fighting Measures:
Hazardous characteristics: non-flammable
Hazardous combustion products: carbon monoxide, carbon dioxide, etc.
Fire extinguishing methods and fire extinguishing media: Move the container from the fire scene to an open area as much as possible. Fire extinguishing media: dry powder, sand